SI-units |
US-units |
Max. operating pressure |
5.0 bar |
72 psi |
Ambient operating temperature |
4°C to 55°C |
39°F to 131°F |
Water temperature All UrSpring Types (with HotWater filter) |
4°C to 40°C (4°C to 70°C) |
39°F to 104°F (39°F to 158°F) |
Storage temperature |
0°C to 55°C |
32°F to 131°F |
pH-range |
pH value of 2 to 11 (during operation) |
|
Chlorine tolerance |
Tolerance for free chlorine: 200,000 ppmh, max. concentration 200 ppm |
|
Pressure difference feed – filtered water |
0 – max. 2.5 bar |
0 - max. 36 psi |
Power supply |
Input: 110-230 Volt AC Output: 12 Volt DC Power consumption: 1.5 W (~ 5.4 during flush) |
|
Total weight (controller unit with wet filter module) |
approx. 15 kg |
approx. 33 lbs |