Part no. |
Description |
Qty |
Service interval |
Task |
Task description |
12587 |
Pressure sensors |
2 |
36 month |
Calibrate sensors |
Re-calibrate sensors through the user interface. |
11351 |
Flow meter |
1 |
36 month |
Function test |
Open tap downstream and check the flow displayed on your unit. If those matches, test is completed. |
12831 |
Flush valve |
1 |
36 month |
Function test |
Check function by performing a manual flush through the control of the UrSpring. |
10646 |
Quick-Connect adapter |
3 |
36 month |
Check for leaks |
|
10545 |
UrSpring Filter |
1 |
36 month |
Replace |
|
Part no. |
Description |
Qty |
Service interval |
Task |
Task description |
10963 |
Pressure relief automatics |
1 |
36 month |
Calibrate Sensors |
Re-calibrate sensors through the user interface. |
10513 |
Flow meter |
1 |
36 month |
Function test |
Open tap downstream and check the flow displayed on your unit. If those matches, test is completed. |
10787 |
Flush valve |
1 |
36 month |
Function test |
Check function by performing a manual flush through the control of the UrSpring. |
10646 |
Quick-Connect adapter |
3 |
36 month |
Check for leaks |
|
10788 |
Only UrSpring HotWater Filter |
1 |
12 month |
Replace |
|
10545 |
all other UrSpring Filters |
1 |
36 month |
Replace |
|